Key Specifications/Special Features
  • INPUT :
    • Input Voltage: 40Vdc to 72Vdc Normal = 56V 
    • Input Current : 2.6A at 40Vdc @Full Load / 1.9A at 56Vdc @Full Load / 1.5A at 72Vdc @F.L
    • *Note: The model isolated design, both positive and negative input are all available.
  • OUTPUT : 
    • Output voltage and current:  56V 
    • Max load: 1.61A
    • Power: 90W maximum
    • Minimum load: 0.01A
    • Load regular percentage: 5%
    • Line regular percentage: 1%
    • Ripple percentage: 1%
    • Noise percentage: 1%
    • Total power: 90W
    • Noise bandwidth is from DC to 20Mhz. Ripple & Noise is measured by Paralleling a 0.1uF metalize capacitor on the test point.  
  • Efficiency:  80% min at Full Load , 40Vdc ~ 72Vdc Input Voltage
  • Protection:
    • Short Circuit Protection
    • Ooutput Short GND Terminal will not damage the Power Supply and will Auto-Reset. 
    • Input with Fuse Protection.
    • Safety Standard : meet EN62368-1.
    • EMC : meet FCC Class A , EN55032 Class A
    • Over Current : 802.3BT Class 8 (96.6W)@All DC Input F.L
    • Input Reverse Protection------NO Work
    • INPUT LOW Voltage Protection Point : 33.2V±0.3V
    • OUTPUT Over Voltage Protection Point : 59V±0.5V 
  • General description
    • Operating temperature: -40 to +70 degree Celsius
    • Storage temperature: -40 to +85 degree Celsius
    • Operating humidity: 5% - 90% non-condensing
    • Free air cooling
    • SIZE : 127*220*46 (L*W*H)m/m (without bracket)
  • Indicates:
    • LED(RED) Indicate power on.
    • Input connector: The device provides M12 A-Code 5 pin connector on the front panel for input, the pin assignments as the figure.
    • M12 X-Code Input (Data Only) and M12 X-Code Output (Data & Power)